Butterfly Valve Test Bench

  • Shell Strength & Sealing Tests
  • For Flanged and Wafer-Type Butterfly Valves
  • Hydraulic Clamping for Reliable Testing
  • Single or Dual-Station Options
  • Customized Solutions Available

Contact Us for a Quote.

Send Inquiry

Description

High-Accuracy Butterfly Valve Test Bench

Product Introduction

The High-Accuracy Butterfly Valve Test Bench is designed for shell strength and sealing tests on flange-type and wafer-type butterfly valves. Available in single-station and dual-station configurations, it meets the testing needs of valve manufacturers and industrial testing facilities.

High Accuracy Butterfly Valve Test Bench

High Accuracy Butterfly Valve Test Bench

Butterfly Valve Test Bench

Butterfly Valve Test Bench

High Accuracy Butterfly Valve Test Bench

High Accuracy Butterfly Valve Test Bench

Key Features

  • Wide Testing Applications: Suitable for shell strength and sealing tests on flange-type and wafer-type butterfly valves.
  • Single or Dual Stations: Flexible configurations to match different testing and production requirements.
  • Hydraulic Clamping: Applies clamping force to the valve ends while minimizing external forces on the valve body.
  • Water and Gas Testing: Supports hydrostatic and pneumatic testing, with a closed-loop water system for water reuse.
  • Automatic Pressure Control: Dual-pump system with automatic pressure holding when the preset pressure is reached.
  • Zero-Pressure Safety Protection: Prevents clamp release until the pressure inside the valve has been relieved.
  • Optional Automation: Safety doors, PLC-based data acquisition, and automated testing functions are available.
  • Customized Solutions: Configurations can be tailored to specific valve dimensions and testing requirements.

Technical Specifications

Model DYFJ-H300 DYFJ-H600 DYFJ-H800 DYFJ-H1200 DYFJ-H1600 DYFJ-
H2000
DYFJ-
H2200
DYFJ-
H2400
Applicable Valve Size (DN) DN50-300 DN50-300 DN50-350 DN300-600 DN350-800 DN1200-
2000
DN1200-
2200
DN1400-
2400
DN300-600 DN400-800 DN700-1200 DN900-1600
Power V
Voltage
380 380 380 380 380 380 380 380
Hz
Frequency
50 50 50 50 50 50 50 50
Motor kW
Power
2.2 3 3 5.5 5.5 7.5 7.5 7.5
Pole 6 6 6 6 6 6 6 6
Range of the water Pressure in a system 0-6.3 0-6.3 0-6.3 0-6.3 0-6.3 0-6.3 0-6.3 0-6.3
Adjustable oil Pressure in the cylinder Max 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5
Allowable OD of flange end of test valve Min 520 845 1085 1485 1930 2345 2475 2760
Allowable OD of flange end of test valve Max 165 440 520 860 1075 1405 1630 1830
Distance between claws & a work table Max 370 370,620 370,637 620,1225 637,1225 1225 1250 1250
(MPa)
Outlet Pressure of a water pump Max
10 10 10 10 10 10 10 10
Overall dim L (mm) 2000 3500 3600 4900 5200 4500 5000 5500
B (mm) 1200 1350 1500 2200 2350 2750 3300 3600
H (am) 1850 1980 2050 2050 2200 2200 2200 2200
Weight (kg) 2000 4500 6000 8000 9800 9000 11500 13000

Applications of the valve test bench

Valve testing is a sequence, not a single measurement — shell test, then seat test on each side, then the record. The Butterfly Valve Test Bench is arranged so the sequence runs without re-clamping the valve between steps.

  • Power plants and refineries — turnaround testing of isolation valves with the tag number recorded against the result.
  • Inspection bodies — independent verification with a traceable test certificate.
  • Valve repair workshops — post-overhaul verification before the valve returns to the plant.

What to specify before we build yours

  • Valve type and size range — ball, gate, globe, butterfly, check or control; each needs a different clamping and sealing arrangement.
  • Pressure class — the bench must exceed the highest class in scope, usually with a margin for the shell test multiplier.
  • Test medium — water, air or gas; the seat-leak measurement method changes with the medium.
  • Test sequence automation — manual valve switching, or a programme that runs shell, seat A and seat B in order and logs each result.

How to choose a valve test bench

The fixture, not the pump, is what makes a valve bench usable day after day:

  • Look at how the valve is clamped. End-loading rams seal against the flange faces; a clamping table holds the body from outside. End-loading is faster for flanged valves, a table is more flexible for threaded and welded-end bodies.
  • Confirm both seat directions are testable. A seat test has to be repeated on the upstream and downstream side of the closure; if the fixture cannot isolate each side, the operator will improvise with blind flanges and lose the cycle time.
  • Decide how leakage is measured. Water gives a visible drip count, air gives a bubble count or a pressure decay, gas gives a flow reading. The bench should report the unit your standard specifies.

Frequently asked questions

What is the difference between a shell test and a seat test?

A shell test pressurises the whole valve body with the closure open or removed, to prove the pressure boundary. A seat test pressurises one side of the closed closure and measures leakage past the seat. Both are required by API 598 and equivalent standards, and they use different circuits.

Can the bench test both metal-seated and soft-seated valves?

Yes. The acceptance criteria differ — metal seats allow a small leakage rate, soft seats are usually required to be bubble-tight — but the fixture and the pressure circuit are the same. The criteria are stored per valve type in the test recipe.

What sizes can one bench cover?

A typical bench covers DN15 to DN300 with interchangeable adapters; larger valves are usually tested with a dedicated end-loading frame. The practical limit is the clamping force and the handling weight, not the pressure rating.

Related equipment and further reading

Need a pressure range, fixture or test standard that is not listed here? Send the specimen list and the standard you test to and we will come back with a configuration and a price within one working day.

Leave Us a Message

Have questions about this product? Fill in the form below and we will reply by email.

Go to Top