Horizontal Valve Test Bench

  • Suitable for Various Flange-Connected Valves
  • Hydraulic Clamping for Reliable Testing
  • Water and Gas Pressure Testing
  • Custom Solutions for Different Valve Sizes

Need a Custom Solution? Contact Us for a Quote.

Send Inquiry

Description

Horizontal Valve Test Bench

Product Introduction

The Horizontal Valve Test Bench is designed for pressure and sealing tests on flange-connected valves, including ball, gate, globe, check, and control valves. Its hydraulic clamping system and dual-pump pressure control provide reliable testing performance and efficient operation.

Suitable for valve manufacturers, testing facilities, and maintenance workshops, the system can be customized to meet different testing requirements.

Horizontal Clamping Valve Test Bench

Horizontal Clamping Valve Test Bench

Horizontal Clamping Valve Test machine

Horizontal Clamping Valve Test machine

Horizontal Valve Test Bench

Horizontal Valve Test Bench

Top Pressure Horizontal Valve Test Bench

Top Pressure Horizontal Valve Test Bench

Key Features

1. Wide Range of Valve Applications

Suitable for testing flange-connected ball valves, gate valves, globe valves, check valves, and control valves.

2. Hydraulic Clamping System

The hydraulic claws clamp the back of the valve flange to seal the valve ends, minimizing external forces on the valve body and helping ensure accurate test results.

3. Optional 90° Rotation

The test bench supports 90-degree rotation for flexible valve positioning during testing. Dual-end rotation is available as an option.

4. Water and Gas Testing

Supports both water and gas testing. Test water can be recycled to reduce water consumption and operating costs. Switching between testing media is controlled through pipeline valves.

5. Dual-Pump Pressure Control

A low-pressure, high-flow pump enables rapid pressurization, while a high-pressure pump gradually increases pressure. The system automatically enters the pressure-holding stage when the preset test pressure is reached.

6. Zero-Pressure Safety Protection

The hydraulic clamping mechanism can only be released when the pressure inside the valve cavity has returned to zero, helping prevent accidental release under pressure.

7. Optional Safety and Automation Features

Available options include safety doors, dual-end 90-degree rotation, PLC-based data acquisition, and automated testing systems.

8. Customized Testing Solutions

Custom designs are available to accommodate different valve dimensions, testing pressures, and specific application requirements.

Technical Specifications

Specification Unit A100 A200 A300 A400 A500 A600 A800 A1000 A1200
Model — DYFJ-A100 DYFJ-A200 DYFJ-A300 DYFJ-A400 DYFJ-A500 DYFJ-A600 DYFJ-A800 DYFJ-A1000 DYFJ-A1200
Applicable Valve Size
Nominal Valve Size (DN) mm 15–100 50–200 80–300 200–400 250–500 300–600 400–800 500–1000 600–1200
Nominal Pressure Range MPa 1.6–32 1.6–32 1.6–32 1.6–32 1.0–16 1.0–16 1.0–16 1.0–16 1.6–16
Valve Face-to-Face Length
Maximum Length mm 350 550 750 950 991 1143 1524 1727 1981
Minimum Length mm 130 180 210 330 380 502 610 711 813
Valve Flange Dimensions
Maximum Flange Diameter / Thickness mm 265/42 405/55 530/83 670/92 775/108 890/108 1085/108 1360/120 1575/120
Minimum Flange Diameter / Thickness mm 90/12 160/16 195/20 355/26 390/28 460/32 520/32 715/34 813/120
Moving Frame Opening Distance
Maximum Distance mm 700 850 1080 1200 1400 1500 2120 2350 2500
Minimum Distance mm 170 250 300 350 400 450 550 650 850
Clamping Mechanism
Axial Stroke mm 52 62 75 80 90 95 100 105 105
Radial Stroke mm 125 150 200 230 250 250 340 340 410
Hydraulic System
Rated Hydraulic Pump Pressure MPa 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3
Pump Flow Rate L/min 6.3 16 25 25 40 40 63 63 63
High-Pressure Booster Range MPa 3–31.5 3–31.5 3–31.5 3–31.5 3–31.5 3–31.5 3–31.5 3–31.5 3–31.5
System Pressure Adjustment Range MPa 0–6.3 0–6.3 0–6.3 0–6.3 0–6.3 0–6.3 0–6.3 0–6.3 0–6.3
Power Supply
Voltage V 380 380 380 380 380 380 380 380 380
Frequency Hz 50 50 50 50 50 50 50 50 50
Electric Motor
Motor Power kW 1.5 2.2 3 3 5.5 5.5 7.5 7.5 7.5
Number of Poles P 4 6 6 6 6 6 6 6 6
Overall Dimensions
Length (L) mm 2550 2820 3100 3350 3750 3900 5200 5500 6000
Width (B) mm 1230 1400 1510 1750 1800 1900 2400 2500 3000
Height (H) mm 1200 1300 1350 1450 1500 1650 2000 2200 2300
Machine Weight kg 1980 2400 3000 4400 5000 5600 8000 12000 14000

Note: Specifications are based on the provided technical data. Customized configurations may be available upon request.

Applications of the valve test bench

Every industrial valve leaves the factory with two questions attached: does the body hold pressure, and does the closure seal. The Horizontal Valve Test Bench answers both on one fixture, with the clamping, the pressure circuits and the record that a valve test procedure expects.

  • Pipeline and EPC contractors — incoming inspection of valves before installation, against API 598 or the project specification.
  • Water and HVAC contractors — pressure testing of butterfly, gate and ball valves before commissioning.
  • Valve manufacturers — routine shell and seat testing at the end of the assembly line.

What to specify before we build yours

  • Valve type and size range — ball, gate, globe, butterfly, check or control; each needs a different clamping and sealing arrangement.
  • Pressure class — the bench must exceed the highest class in scope, usually with a margin for the shell test multiplier.
  • Test medium — water, air or gas; the seat-leak measurement method changes with the medium.
  • Test sequence automation — manual valve switching, or a programme that runs shell, seat A and seat B in order and logs each result.

How to choose a valve test bench

The fixture, not the pump, is what makes a valve bench usable day after day:

  • Look at how the valve is clamped. End-loading rams seal against the flange faces; a clamping table holds the body from outside. End-loading is faster for flanged valves, a table is more flexible for threaded and welded-end bodies.
  • Confirm both seat directions are testable. A seat test has to be repeated on the upstream and downstream side of the closure; if the fixture cannot isolate each side, the operator will improvise with blind flanges and lose the cycle time.
  • Decide how leakage is measured. Water gives a visible drip count, air gives a bubble count or a pressure decay, gas gives a flow reading. The bench should report the unit your standard specifies.

Frequently asked questions

What is the difference between a shell test and a seat test?

A shell test pressurises the whole valve body with the closure open or removed, to prove the pressure boundary. A seat test pressurises one side of the closed closure and measures leakage past the seat. Both are required by API 598 and equivalent standards, and they use different circuits.

Can the bench test both metal-seated and soft-seated valves?

Yes. The acceptance criteria differ — metal seats allow a small leakage rate, soft seats are usually required to be bubble-tight — but the fixture and the pressure circuit are the same. The criteria are stored per valve type in the test recipe.

What sizes can one bench cover?

A typical bench covers DN15 to DN300 with interchangeable adapters; larger valves are usually tested with a dedicated end-loading frame. The practical limit is the clamping force and the handling weight, not the pressure rating.

Related equipment and further reading

Need a pressure range, fixture or test standard that is not listed here? Send the specimen list and the standard you test to and we will come back with a configuration and a price within one working day.

Leave Us a Message

Have questions about this product? Fill in the form below and we will reply by email.

Go to Top